Validation of midsagittal jaw movements to measure sleep in healthy adults by comparison with actigraphy and polysomnography

dc.rights.licenseCC0en_US
dc.contributor.authorChakar, Bassam
dc.contributor.authorSENNY, Frédéric
dc.contributor.authorPoirrier, Anne-Lise
dc.contributor.authorCambron, Laurent
dc.contributor.authorFanielle, Julien
dc.contributor.authorPoirrier, Robert
dc.date.accessioned2020-03-04T14:31:37Z
dc.date.available2020-03-04T14:31:37Z
dc.date.issued2017
dc.identifier.issn1984-0063en_US
dc.identifier.urihttps://luck.synhera.be/handle/123456789/233
dc.description.abstract10, 3 (2017), p. 122-127en_US
dc.description.abstractfrObjectif: Dans un appareil basé sur l'analyse des mouvements de la mâchoire médio-sagittale, nous avons évalué un sommeil-éveil détecteur automatique comme méthode objective pour mesurer le sommeil chez des adultes en bonne santé par actigraphie du poignet contre la polysomnographie (PSG). Méthodes: inlab simultané et synchronisé PSG, actigraphie du poignet et mouvements de la mâchoire ont été effectués chez 38 participants en bonne santé. Époque par analyse d'époque a été réalisée pour évaluer la capacité de distinction sommeil-éveil. Paramètres de sommeil comme mesurés par les trois appareils ont été comparés. Cela comprenait trois paramètres régulièrement signalés: temps total de sommeil, latence de sommeil et réveil après le sommeil. De plus, deux paramètres supplémentaires, réveil pendant la période de sommeil et le temps de latence, ont été ajoutés pour mesurer l'état de veille tranquille. Résultats: Les mouvements de la mâchoire ont montré un niveau de sensibilité égal à l'actigraphie de 96% et un niveau de spécificité plus élevé (64% et 48% respectivement). Le niveau d'accord entre les deux appareils était élevé (87%). le l'analyse de leur désaccord par une résolution de divergence analyse a utilisé PSG comme résolveur a révélé que la mâchoire les mouvements étaient justes (58,9%) plus souvent que l'actigraphie (41%). Dans la comparaison des paramètres de sommeil, la corrélation de coefficient des mouvements de mâchoire était plus élevée que l'actigraphie dans tous les paramètres. En outre, sa capacité à distinguer l'état veille-sommeil a permis une estimation plus efficace des paramètres mesuré l'état de veille tranquille. Conclusions: l'analyse des mouvements de la mâchoire médio-sagittale est un méthode pour mesurer le sommeil. Chez l'adulte en bonne santé, ce dispositif s'est révélé supérieur à l'actigraphie en termes d'estimation de tous les paramètres du sommeil et distinction du statut veille-sommeil.en_US
dc.description.abstractenObjective: In a device based on midsagittal jaw movements analysis, we assessed a sleep-wake automatic detector as an objective method to measure sleep in healthy adults by comparison with wrist actigraphy against polysomnography (PSG). Methods: Simultaneous and synchronized inlab PSG, wrist actigraphy and jaw movements were carried out in 38 healthy participants. Epoch by epoch analysis was realized to assess the ability to sleep-wake distinction. Sleep parameters as measured by the three devices were compared. This included three regularly reported parameters: total sleep time, sleep onset latency, and wake after sleep onset. Also, two supplementary parameters, wake during sleep period and latency time, were added to measure quiet wakefulness state. Results: The jaw movements showed sensitivity level equal to actigraphy 96% and higher specificity level (64% and 48% respectively). The level of agreement between the two devices was high (87%). The analysis of their disagreement by discrepant resolution analysis used PSG as resolver revealed that jaw movements was right (58.9%) more often than actigraphy (41%). In sleep parameters comparison, the coefficient correlation of jaw movements was higher than actigraphy in all parameters. Moreover, its ability to distinct sleep-wake state allowed for a more effective estimation of the parameters that measured the quiet wakefulness state. Conclusions: Midsagittal jaw movements analysis is a reliable method to measure sleep. In healthy adults, this device proved to be superior to actigraphy in terms of estimation of all sleep parameters and distinction of sleep-wake status.en_US
dc.description.tableofcontentsMETHODS Subjects Polysomnography Wrist-Actigraphy (WAC) Jaw movements device (JAWAC) Procedures Analysis Data analysis RESULTS Participants Epoch-by-Epoch analysis results Sleep parameters analysis results DISCUSSION CONCLUSION REFERENCESen_US
dc.language.isoENen_US
dc.publisherBrazilian Sleep Societyen_US
dc.relation.ispartofSleep Scienceen_US
dc.rights.uri?en_US
dc.subjectActigraphyen_US
dc.subjectMovementen_US
dc.subjectSleep Wake Disordersen_US
dc.subjectSleepen_US
dc.subject.enActigraphieen_US
dc.subject.enMouvementen_US
dc.subject.enTroubles du sommeil et de l'éveilen_US
dc.subject.enSommeilen_US
dc.titleValidation of midsagittal jaw movements to measure sleep in healthy adults by comparison with actigraphy and polysomnographyen_US
dc.title.frValidation des mouvements de la mâchoire médio-sagittale mesurer le sommeil chez des adultes en bonne santé par comparaison avec actigraphie et polysomnographieen_US
dc.typeArticle scientifiqueen_US
synhera.classificationSciences de la santé humaineen_US
synhera.institutionHELMoen_US
synhera.otherinstitutionULiègeen_US
synhera.stakeholders.fund?en_US
synhera.cost.total0en_US
synhera.cost.apc0en_US
synhera.cost.comp0en_US
synhera.cost.acccomp0en_US
dc.description.versionOuien_US
dc.rights.holder?en_US


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée