Afficher la notice abrégée

High Specificity of Single Inertial Sensor-Supplemented Timed Up and Go Test for Assessing Fall Risk in Elderly Nursing Home Residents

dc.rights.licenseCC1en_US
dc.contributor.authorBUISSERET, Fabien
dc.contributor.authorSchütz, Gaston
dc.contributor.authorStoffel, Pierre-Loup
dc.contributor.authorDIERICK, Frédéric
dc.date.accessioned2022-04-19T07:06:43Z
dc.date.available2022-04-19T07:06:43Z
dc.date.issued2022-02-17
dc.identifier.urihttps://luck.synhera.be/handle/123456789/1609
dc.identifier.doi10.3390/s22062339en_US
dc.description.abstractThe Timed Up and Go test (TUG) is commonly used to estimate the fall risk in the elderly. Several ways to improve the predictive accuracy of TUG (cameras, multiple sensors, other clinical tests) have already been proposed. Here, we added a single wearable inertial measurement unit (IMU) to capture the residents’ body center-of-mass kinematics in view of improving TUG’s predictive accuracy. The aim is to find out which kinematic variables and residents’ characteristics are relevant for distinguishing faller from non-faller patients. Data were collected in 73 nursing home residents with the IMU placed on the lower back. Acceleration and angular velocity time series were analyzed during different subtasks of the TUG. Multiple logistic regressions showed that total time required, maximum angular velocity at the first half-turn, gender, and use of a walking aid were the parameters leading to the best predictive abilities of fall risk. The predictive accuracy of the proposed new test, called i + TUG, reached a value of 74.0%, with a specificity of 95.9% and a sensitivity of 29.2%. By adding a single wearable IMU to TUG, an accurate and highly specific test is therefore obtained. This method is quick, easy to perform and inexpensive. We recommend to integrate it into daily clinical practice in nursing homes.en_US
dc.description.sponsorshipNoneen_US
dc.language.isoENen_US
dc.publisherMDPIen_US
dc.relation.ispartofSensorsen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.subjectRisk of fallen_US
dc.subjectIMUen_US
dc.subjectTUGen_US
dc.subjectLogistic regressionen_US
dc.titleHigh Specificity of Single Inertial Sensor-Supplemented Timed Up and Go Test for Assessing Fall Risk in Elderly Nursing Home Residentsen_US
dc.typeArticle scientifiqueen_US
synhera.classificationIngénierie, informatique & technologieen_US
synhera.institutionCeREF Techniqueen_US
synhera.otherinstitutionUMONSen_US
synhera.otherinstitutionRehazenteren_US
synhera.otherinstitutionUCLouvainen_US
synhera.cost.total0en_US
synhera.cost.apc0en_US
synhera.cost.comp0en_US
synhera.cost.acccomp0en_US
dc.description.versionOuien_US
dc.rights.holderMDPIen_US


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

CC1
Excepté là où spécifié autrement, la license de ce document est décrite en tant que CC1